Beater driver

Beater driver

Technical parameters of the beater controller:

- RS 485 interface (separated)

- 24 V DC supply

- 4 relay outputs

- 2 DC (transistor) outputs

- 2 semiconductor outputs for voltage: 230V AC - (switching on at zero)

- 9 separated digital inputs powered by a built-in 24 V DC power supply

-1 analog 0-10V input for measuring the temperature with a pyrometer

- mini USB interface for connecting a PC - console / software change program

- built-in real time clock (RTC)

- memory for 50 recipes (technological programs)

- alarm handling

- built-in function to continue operation after a power outage

- power supply: 24 V DC

Beater driver

We invite machinery and equipment  manufacturers to cooperate with us.

Contact mobile  513 032 231   lub wyślij wiadomość

We cooperate with